TECK90 armoured cable CSA Type HL 1000V is a high-performance cable designed for industrial environments with excellent mechanical protection and outstanding environmental adaptability. The cable uses a single-core bare copper conductor, covered with XLPE (cross-linked polyethylene) insulation, equipped with a spirally wrapped grounding wire, an inner layer of PVC sheath, and an armored structure of aluminum interlocking armor (AIA). The outer layer is also a weather-resistant PVC sheath, and the overall structure is sturdy and durable. The cable is rated for 90℃, and the conductor size range covers 250 kcmil to 750 kcmil, which is suitable for various medium and high load power supply scenarios.
Ansökan
TECK90 cable is marked as direct burial and sunlight resistant, suitable for long-term operation in underground pipelines or exposed environments, especially suitable for projects that require high weather resistance and fire resistance, such as mines, tunnels, ports, power plants, and heavy manufacturing workshops. It has passed the -40℃cold shock test and FT1/FT4, IEEE 1202 Flamhämndtest, säkerställer stabil drift även i extremt kall, högtemperatur eller mycket frätande miljöer . Dessutom används denna kabel också vanligtvis för huvudkraftsförsörjning mellan substationer, kraftproduktionsutrustning och styrsystem, eller som en kraftanslutning för nyckelutrustning som stora motorer, pumpar, kompressorer, HVAC-system osv. Krav . Designen säkerställer säkerheten för personal och utrustning samtidigt som man förbättrar ledningseffektiviteten och den totala systemets tillförlitlighet .

Certifiering
TECK90 cable has passed a number of authoritative certifications, including compliance with CSA standards C22.2 No. 131 and No. 174, and has a CSA HL rating. Its "direct burial" and "sunlight-resistant" markings mean that no additional protection measures are required after installation, which can reduce construction costs and labor Komplexitet . För det andra ger den pansarstrukturen utmärkt motstånd mot mekanisk skada, vilket minskar risken för kabelfel orsakade av kollision, komprimering eller bitande, därmed minskar underhållsfrekvensen och operationell avbrottstid . Dessutom uppfyller kabelen.

Paket

Produktionslinje

Greater Wire är en professionell Teck90-pansarkabeltillverkare . Vår fabrik är utrustad med avancerade automatiserade produktionslinjer och högprecisionstestutrustning, som kan uppnå fullprocesskvalitetskontroll från ledare, isolering extruering, rustningsformning, till final mantel extrudering . varje satch av trådar under multipel processer, sådan såsom 5 {5} cold cold cold chock, cold chock, ft chock, ft cold chock, ft chock, ft chock, ft cold cold cold cold cold cold cold cold randing, flamskyddstest och tål spänningsisoleringstest för att säkerställa att produkten fortfarande kan fungera säkert och stabilt i extrema miljöer .
kund

Partner

Hot Tags: Teck90 Armored Cable Single Core CSA Type HL 1000V, China Teck90 Armored Cable Single Core CSA Type HL 1000V Tillverkare, leverantörer, fabrik

| Ledarstorlek (Stranding) |
Antal ledare | Jordtrådstorlek (AWG) |
Nominell diameter över isolering (MILS) |
Nominell diameter över rustning (I) |
Nominell kabeldiameter (i) | Ca . Nettovikt (Lbs/1000 ft) |
Ca . Nettovikt (Kg per km) |
| 14(7W) | 2 | 14 | 0.13 | 0.58 | 0.67 | 195 | 290 |
| 14(7W) | 3 | 14 | 0.13 | 0.6 | 0.69 | 226 | 336 |
| 14(7W) | 4 | 14 | 0.13 | 0.64 | 0.72 | 256 | 381 |
| 14(7W) | 5 | 14 | 0.13 | 0.68 | 0.76 | 290 | 432 |
| 14(7W) | 6 | 14 | 0.13 | 0.72 | 0.8 | 316 | 471 |
| 14(7W) | 7 | 14 | 0.13 | 0.74 | 0.82 | 338 | 503 |
| 14(7W) | 8 | 14 | 0.13 | 0.79 | 0.87 | 373 | 555 |
| 14(7W) | 10 | 14 | 0.13 | 0.88 | 0.96 | 451 | 671 |
| 14(7W) | 12 | 14 | 0.13 | 0.9 | 0.99 | 511 | 761 |
| 14(7W) | 15 | 14 | 0.13 | 0.96 | 1.04 | 586 | 872 |
| 14(7W) | 20 | 14 | 0.13 | 1.13 | 1.21 | 789 | 1174 |
| 12(7W) | 2 | 14 | 0.15 | 0.62 | 0.70 | 228 | 340 |
| 12(7W) | 3 | 14 | 0.15 | 0.65 | 0.73 | 254 | 378 |
| 12(7W) | 4 | 14 | 0.15 | 0.69 | 0.77 | 293 | 436 |
| 12(7W) | 5 | 14 | 0.15 | 0.73 | 0.81 | 350 | 521 |
| 10(7W) | 2 | 12 | 0.18 | 0.67 | 0.75 | 275 | 410 |
| 10(7W) | 3 | 12 | 0.18 | 0.70 | 0.78 | 327 | 487 |
| 10(7W) | 4 | 12 | 0.18 | 0.74 | 0.83 | 413 | 615 |